Natural Gas-Liquid Fuel Triple Pass Prismatic
| Price : | Ask For Price |
| Ad Code : | M-157465 |
| Ad Type : | For Sale - New |
| Views : | 994 |
| Date Updated : | 14 Nov 2025 |
| Production Type : | Brand |
| Brand : | AKTES |
| Production Year : | 2025 |
Aktes Pazarlama
Türkiye - Adıyaman - merkez
HOCAÖMER MAH.GÖLBAŞI CAD NO 30 KAT 2
MERKEZ / ADIYAMAN
Natural Gas-Liquid Fuel Triple Pass Prismatic Ad Description
Natural Gas–Liquid Fuel Three-Pass Prismatic – SSS –
SSS Type, Gas – Liquid Fuel Prismatic Three-Pass Hot Water Boiler
Capacity range: 100,000 – 300,000 kcal/h
- Especially suitable for natural gas operation.
- Can also be used with fuel oil, diesel, and LPG.
- With a wide capacity range, SSS boilers are an excellent choice for space heating and domestic hot water production.
- Designed as three-pass boilers, delivering very high efficiency.
- Boiler width reduced and height increased.
- This design provides much more heat-transfer surface for maximum heating performance.
- High combustion efficiency thanks to the design.
Technical Data Table – SSS Type Gas–Liquid Fuel Three-Pass Hot Water Boiler
| Product Code | Thermal Power (kcal/h) | kW | L (mm) | l (mm) | D (mm) | H (mm) | ØD (mm) | Flow/Return Connection | Flow Safety | Approx. Weight 3 bar (kg) | Approx. Weight 4 bar (kg) | Gas-Side Resistance (mbar) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SSS100 | 100,000 | 116 | 1420 | 1045 | 665 | 1165 | 150 | DN65 | 1″ | 390 | 429 | 0.9 |
| SSS125 | 125,000 | 145 | 1520 | 1144 | 665 | 1135 | 150 | DN65 | 1″ | 450 | 495 | 0.9 |
| SSS150 | 150,000 | 175 | 1670 | 1290 | 665 | 1160 | 150 | DN65 | 1″ | 500 | 550 | 1.2 |
| SSS175 | 175,000 | 203 | 1734 | 1310 | 726 | 1317 | 200 | DN65 | 1 1/4″ | 585 | 645 | 1.2 |
| SSS200 | 200,000 | 233 | 1834 | 1410 | 726 | 1317 | 200 | DN65 | 1 1/4″ | 650 | 715 | 1.8 |
| SSS250 | 250,000 | 291 | 1811 | 1430 | 777 | 1400 | 200 | DN65 | 1 1/2″ | 800 | 880 | 2.0 |
| SSS300 | 300,000 | 349 | 1877 | 1500 | 777 | 1401 | 250 | DN80 | 1 1/2″ | 800 | 968 | 2.2 |
The values in the table may vary by ±5%. We reserve the right to make changes to dimensions and models. Our company cannot be held responsible for printing errors in the measurements.
SSS Type, Gas – Liquid Fuel Prismatic Three-Pass Hot Water Boiler
Capacity range: 350,000 – 900,000 kcal/h
- Especially suitable for natural gas operation.
- Can also be used with fuel oil, diesel, and LPG.
- With a wide capacity range, SSS boilers are an excellent choice for space heating and domestic hot water production.
- Designed as three-pass boilers, delivering very high efficiency.
- Boiler width reduced and height increased.
- This design provides much more heat-transfer surface for maximum heating performance.
- High combustion efficiency thanks to the design.
Technical Data Table – SSS Type Gas–Liquid Fuel Three-Pass Hot Water Boiler
| Product Code | Thermal Power (kcal/h) | kW | L (mm) | l (mm) | D (mm) | H (mm) | ØD (mm) | Flow/Return Connection | Flow Safety | Approx. Weight 3 bar (kg) | Approx. Weight 4 bar (kg) | Gas-Side Resistance (mbar) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SSS350 | 350,000 | 407 | 2066 | 1550 | 866 | 1607 | 250 | DN80 | 1 1/2″ | 1100 | 1210 | 2.2 |
| SSS400 | 400,000 | 465 | 2160 | 1650 | 868 | 1607 | 250 | DN80 | 1 1/2″ | 1250 | 1375 | 2.4 |
| SSS450 | 450,000 | 523 | 2263 | 1750 | 914 | 1660 | 250 | DN80 | 1 1/2″ | 1350 | 1485 | 2.8 |
| SSS500 | 500,000 | 581 | 2363 | 1850 | 914 | 1580 | 300 | DN100 | 1 1/2″ | 1500 | 1650 | 2.8 |
| SSS550 | 550,000 | 640 | 2360 | 1860 | 934 | 1670 | 300 | DN100 | 1 1/2″ | 1550 | 1705 | 3.4 |
| SSS600 | 600,000 | 698 | 2474 | 1900 | 982 | 1766 | 300 | DN100 | 1 1/2″ | 1650 | 1815 | 4.0 |
| SSS700 | 700,000 | 814 | 2574 | 2000 | 982 | 1678 | 350 | DN100 | 1 1/2″ | 1950 | 2145 | 4.5 |
| SSS800 | 800,000 | 930 | 2705 | 2150 | 1008 | 1930 | 350 | DN100 | 2″ | 2250 | 2495 | 5.0 |
| SSS900 | 900,000 | 1047 | 2905 | 2350 | 1008 | 1930 | 350 | DN125 | 2″ | 2450 | 2650 | 5.5 |
The values in the table may vary by ±5%. We reserve the right to make changes to dimensions and models. Our company cannot be held responsible for printing errors in the measurements.